Robust & Reproducible Sample Preparation for LC/MS

Porvair Sciences has published an in-depth application report demonstrating how their Microlute® CP Reverse Phase Solid Phase Extraction (SPE) microplates provide a robust and highly reproducible SPE LC-MS sample preparation methodology for a range of neutral, acidic, and basic analytes.

Microlute CP hybrid Solid Phase Extraction technology .Image credit: Porvair Sciences

As a sample preparation method - Solid Phase Extraction is widely acknowledged as a 'go to' tool for the clean-up of samples before analysis by hyphenated techniques such as LC/MS or GC/MS. Solid Phase Extraction offers several advantages to the analyst, including less system downtime and troubleshooting, cleaner chromatograms with a reduction of contaminating compounds, and greater reproducible analyte recoveries. Unfortunately, traditional SPE methods rely upon loose-filled resins which often create problems such as voids in the sorbent beds leading to channeling and inconsistent flow-through of solutions. These undesirable effects lead to reduced interactions between analytes and the active resin resulting in inconsistent results and poor analyte recovery.

Acidic analyte recovery - %RSD comparison of Microlute CP against competitor SPE products. Image credit: Porvair Sciences

Designed to overcome these shortfalls - Microlute® CP SPE microplates from Porvair Sciences, incorporate a unique, polymer structure made up of an interconnected network of evenly distributed pores combined with retentive media. This hybrid technology ensures even liquid flow rates throughout the SPE process, which leads to sufficient time for Van der Waals forces of interaction to take place between the solid phase sorbent and the analytes resulting in a highly reproducible SPE method.

Experimental data is provided in the application report to show how Microlute® CP RP 96 well microplates selectively retain and elute a wide range of neutral, basic, and acidic compounds. The data demonstrate how percentage relative standard deviation values from the Microlute® CP are on average significantly lower than using other commercial SPE plates, thereby producing more reproducible results. In addition, the application note demonstrates that no analyte is lost in the load step of the SPE process leading to high recovery values for all types of compounds. The Microlute® CP RP 96 well-plate for solid phase extractions is also shown to offer significant benefits for the recovery of hydrophobic basic analytes.

Microlute CP products. Image credit: Porvair Sciences

To read the application report in full please visit https://www.microplates.com/resources/evaluation-of-the-microlute-cp-reversed-phase-rp-solid-phase-extraction-96-well-plate-by-hplc-ms/. For further information on Microlute® CP Reverse Phase Solid Phase Extraction (SPE) microplates please visit https://www.microplates.com/microlute-cp/ or contact Porvair Sciences at  [email protected] or call +44 1978 666222 / +1 800 552 3696.

Porvair Sciences, together with JG Finneran and Porvair Kbiosytems are global manufacturers of consumables and instruments for life science and analytical workflows. From microplate technologies, glass vials, assay kits to automated laboratory equipment, the group is committed to equipping customers with high quality products for improved analysis and increased productivity to accelerate scientific discovery with integrity.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Porvair Sciences Limited. (2021, November 18). Robust & Reproducible Sample Preparation for LC/MS. AZoLifeSciences. Retrieved on November 24, 2024 from https://www.azolifesciences.com/news/20211118/Robust-Reproducible-Sample-Preparation-for-LCMS.aspx.

  • MLA

    Porvair Sciences Limited. "Robust & Reproducible Sample Preparation for LC/MS". AZoLifeSciences. 24 November 2024. <https://www.azolifesciences.com/news/20211118/Robust-Reproducible-Sample-Preparation-for-LCMS.aspx>.

  • Chicago

    Porvair Sciences Limited. "Robust & Reproducible Sample Preparation for LC/MS". AZoLifeSciences. https://www.azolifesciences.com/news/20211118/Robust-Reproducible-Sample-Preparation-for-LCMS.aspx. (accessed November 24, 2024).

  • Harvard

    Porvair Sciences Limited. 2021. Robust & Reproducible Sample Preparation for LC/MS. AZoLifeSciences, viewed 24 November 2024, https://www.azolifesciences.com/news/20211118/Robust-Reproducible-Sample-Preparation-for-LCMS.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of AZoLifeSciences.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Medical device components that inhibit bacterial growth